- Overview
- Features
- Tech Specs
- Configurations
- PDF Downloads
- Product Videos
- Reviews
- Cooling Capacity @ 55 F: 3694 BTUH
- Capacity (cu. ft.): 1000
- Decibels (L/H): 63
- Dedicated Circuit: 15 Amp
- Power: 115V AC / 60 Hz
- Refrigerant: R134A
CellarPro Ceiling Mount Recessed 4000Scmr-EC (P/N 34217). NOW WITH ENERGY-EFFICIENT EC FANS! CellarPro engineered the Ceiling Mount Mini-Split 4000Scmr-EC cooling system to provide maximum cooling power and adjustable humidity control with a ceiling-mounted evaporator that can be recessed in the ceiling and therefore hidden from view. The condensing unit can be configured for indoor or exterior installations, and the evaporator includes a variable-speed fan with a low setting for quieter operation and a high setting for maximum power.
All air-cooled refrigeration equipment requires fresh air intake to dissipate the heat generated by the cooling unit. The fresh air intake CANNOT come from the wine cellar space - it must come from space outside the cellar.
♦ View more of our CellarPro Products
♦ Click to view more CellarPro Units
- Now with energy-efficient EC Fans on the cold side, save $72.04 in annual energy costs vs AC fans (assumes 75% runtime and $0.15/kWh)
- This unit is designed to separate the heat and noise from the condensing unit from interior living spaces, and can be configured to operate indoors or outdoors in extreme temperature conditions ranging from -20 to 110F.
- Our Evaporators are built with high-output centrifugal fans which include variable speed settings for your choice of maximum cooling power at the high fan speed, or quieter operation (54 decibels) at the low fan speed.
- Adjustable humidity control combines a high-output compressor with flexible fan cycles to maintain a recommended level of moisture inside your cellar.
- Extra-large coils generate maximum cooling power inside the cellar.
- Excess condensate is managed through an internal integrated condensate pump 1/4" drain line that exits from a choice of knockouts in the evaporator. The pump has automatic overflow protection.
- Commercial-grade Electrofin coating protects the evaporator coils from leaks and corrosion.
- Remote LED display panel and digital programmable controls includes 20-feet of wiring and can be mounted inside or outside the cellar.
- Quick-chill mode, and auto-defrost cycle provide convenient solutions to common cellar needs.
- Temperature set point range is 47F to 62F when the cooling unit is properly sized.
- Unit operates with minimal vibrations and less noise than comparable units from competitors.
- Audible and visual alarms and maintenance-needed indicator protect the cooling unit and the wine cellar.
- Common dedicated 15-amp circuit is required to power the unit.
- Factory-installed Expansion Valve and Liquid Line Solenoid Valve (optional) ensure maximum operating precision and range.
- Refrigerant access valve provides access to the internal components for servicing and repair.
- Sight Glass and Liquid Line Filter/Drier are included for easy installation and maintenance.
- Oversized Receiver allows for long line sets up to 100 equivalent feet and up to 30 vertical feet.
- Auto-reset high-pressure switch protects the system by interrupting power to the compressor when system pressure is too high.
- Evaporator and Condensing Unit are factory-pressurized and shipped with dry nitrogen to ensure leak-free installation.
- CellarPro's 2-Year/5-Year Warranty, the most thorough in the industry, protects the unit against manufacturing defects.
- An optional Extended Warranty (P/N 31489) is available for additional protection.
- ETL Tested and Certified to rigorous UL Standards for safety.
- Model: 4000Scmr-EC
- Cellar Size(Nominal Cu Ft)*: 1000
- Compressor Size (HP): 1/2 Ton
- BTUH @ 55F / Evaporator Decibels
- Low Fan Speed: 3059 BTUH / 51 dbA
- Medium Fan Speed: 3538 BTUH / 55 dbA
- High Fan Speed: 3694 / 63 dbA
- Condensing Unit Decibels (Indoor/ Outdoor): 64/ 62
- Amps (Starting/Running): 40.0/ 8
- Application: Indoor/ Outdoor
- Max Ambient Temp ̊F: 110
- Decibels (L/H): 63
- Power: 115V AC/ 60Hz
- Cold Intake/ Exhaust: Bottom
- Hot Intake/ Exhaust: Rear/Front
- Dedicated Circuit: 15 Amp
- Refrigerant: R134a
Size (W x D x H ‐inches) / Weight (lbs)
- 35.75W x 14.125D x 12.75H / 136 lbs
- CellarPro 4000Scm units are designed to be installed with the evaporator recessed in the ceiling above the cellar, and the condensing unit in a remote location.
- Our Split refrigeration systems offer a choice of wiring:
- The Condensing unit can be electronically controlled by and wired to the Evaporator (single power source on the Evaporator side). This configuration allows the Condensing unit to be used in temperatures down to 20F with the addition of our compressor heater, or down to -20F with the addition of our fan cycling switch AND compressor heater. This configuration requires a 15-amp dedicated circuit breaker for 3000Scmr and 4000Scmr-EC systems, and a 25-amp dedicated circuit breaker for 6000Scmr and 8000Scmr systems.
- The Condensing unit can be controlled by a Solenoid valve (dual power source, one each to the Evaporator and Condensing units.) This configuration allows the Condensing unit to be used in temperatures down to 20F with the addition of our compressor heater. This configuration requires the evaporator to be wired to a 15-amp circuit breaker, and the condensing unit to be wired to a dedicated 15-amp circuit breaker for 3000Scmr and 4000Scmr-EC systems, a dedicated 20-amp circuit breaker for 6000Scmr systems, and a dedicated 25-amp circuit breaker for 8000Scmr systems
- The condensing unit requires 12 inches of unobstructed space in front of the coils, and requires approx. 600-700 CFM of ventilation when installed in a confined space.
- For outdoor installations, we offer an outdoor hood to protect the condensing unit from weather. All outdoor hoods include a compressor heater.
- All split systems must be installed and charged on site by a qualified HVAC professional. Line-set equivalent feet must be calculated in accordance with ASHRAE guidelines; refer to our Line Sizing Chart for more information.
- A CellarPro cooling unit must always be used in the upright position, and should never be operated on its side or upside down.