- Overview
- Features
- Tech Specs
- Configurations
- PDF Downloads
- Reviews
- Cooling Capacity @ 12.8 C: 1745 BTUH
- Dedicated Circuit: 15 Amp
- Power: 115VAC/ 60Hz
- Refrigerant: R134A
CellarPro 2000VSi-ECX 220V / 50Hz Cooling Unit (P/N 27248). NOW WITH ENERGY-EFFICIENT EC FANS! CellarPro engineered the low profile 2000VSi-ECX cooling unit specifically for installations in wine cellars with limited space.
Just 14 1/8-inches (358mm) wide and 13 1/4-inches (338mm) tall, the 2000VSi-ECX cooling unit will fit in between studs and/or above door frames. Dual independent variable-speed fans offer flexibility to trade-off between super-quiet operation vs maximum performance.
All air-cooled refrigeration equipment requires fresh air intake to dissipate the heat generated by the cooling unit. The fresh air intake CANNOT come from the wine cellar space - it must come from space outside the cellar.
♦ View more of our CellarPro Products
♦ Click to view more CellarPro Units
- Features energy-efficient EC Fans on both the cold and hot sides
- Intuitive LED display panel mounted on the evaporator with digital programmable thermostat is simple and easy to use. Remote thermostat is available as an upgrade
- Adjustable humidity control combines a high-output compressor with flexible fan cycles to maintain a recommended level of moisture inside your cellar.
- Commercial-grade Electrofin coating protects the evaporator and condenser coils from leaks and corrosion.
- Low profile for maximum flexibility
- Shallow height fits above doors: 13 1/4" H
- Shallow width fits in between studs: 14 1/8" W
- Variable-speed fan inside the cellar
- 1745 BTUH on high fan speed
- 1581 BTUH on low fan speed
- Variable-speed fan outside the cellar
- 43C maximum intake temperature / 61.5 dBA on the high fan speed
- 38C maximum intake temperature / 55.5 dBA on the low fan speed
- Condensate management system
- Oversized stainless-steel drain pan
- 12.7mm ID drain line for excess condensate
- Optional 100W heating element
- Energy-saver mode, quick-chill mode, and auto-defrost cycle provide convenient solutions to common cellar needs.
- Temperature set point range is 47F to 62F when the cooling unit is properly sized.
- Unit operates with minimal vibrations and less noise than comparable units from competitors.
- Audible and visual alarms and maintenance-needed indicator protect the cooling unit and the wine cellar.
- With dual power sources and a 10-foot power cord, the unit can be plugged into a receptacle from either the front or the rear of the cooling unit, providing flexibility for most installations.
- Common dedicated 15-amp circuit is required to power the unit.
- Our easy-access air filter protects the condenser coils and increases the expected useful life of the cooling unit.
- Adjustable mounting brackets, included as standard equipment, ensure easy installation.
- Removable steel case and refrigerant access valve provides access to the internal components for servicing and repair.
- CellarPro's 1-Year Standard Warranty, the most thorough in the industry, protects the unit against manufacturing defects.
- Model: 2000VSi-ECX
- Cellar Size(Nominal Cu Ft)*: 400
- Compressor Size (HP): 1/4 Ton
- BTUH @ 12.8C: 1745
- CFM (High Fan Speed): 188
- Decibels (Low Fan Speed): 56
- Installation Environment: Indoor
- Ambient Intake Range: -20** to 110F
- Power: 220V AC/ 50Hz
- Amps (Starting/Running): 13.5/ 2.39
- Dedicated Circuit: 15-Amp
- Refrigerant: R134a
- Drain Line: Included -1/2" ID
- Ducting - Cold Side: Yes –6" Diam.
- Ducting - Hot Side: Yes –6" Diam.
Dimensions
- Size (W x D x H -inches): 14.1 x 22.3 x 13.3
- Weight (lbs): 72
- CellarPro 2000VSi-ECX units are self-contained, fully-charged units designed to be attached to the ceiling inside the cellar, or above the cellar.
- 2000VSx-ECX units also can be located remotely from the cellar with the addition of one of our cold-side duct packages. Offered with or without insulated flex ducting, in a choice of configurations for low or high humidity conditions, our front duct packages allow these cooling units to be ducted up to 15.24 equivalent meters away from the cellar. Ducting must be 203mm (or greater) from start to finish.
- When calculating equivalent feet, each 90-degree turn counts for 2.4 meters.
- For remote or inaccessible installations, we offer a remote control display kit which is wired to the cooling unit and allows the digital display to be mounted inside or outside the cellar.
- 2000VSi-ECX cooling units require fresh air intake without interference from the unit's hot air exhaust. If sufficient space does not exist to provide fresh air, you may need our hot-side duct kit.
- If the fresh air intake (on the hot side) will pull air below below 4.4C, the cooling unit will require our Compressor Heater (P/N 1727) .
- If the fresh air intake (on the hot side) will pull air below -6.7C down to -29C, we recommend our Fan-Cycling Switch (P/N 6972) combined with our compressor heater.
- The cooling unit should never be exposed to temperatures below 32F (0C).
- A CellarPro cooling unit must always be used in the upright position, and should never be operated on its side or upside down.