- Cooling Capacity @ 55 F: 1886 BTUH
- Dedicated Circuit: 15 Amp
- Power: 115VAC/ 60Hz
- Cooling Unit dBA: 56
- Refrigerant: R134A
CellarPro 2000VSi-ECX Cooling Unit (P/N 27056). NOW WITH ENERGY-EFFICIENT EC FANS! CellarPro engineered the low profile 2000VSi-ECX cooling unit specifically for installations in wine cellars with limited space.
Just 14 1/8-inches wide and 13 1/4-inches tall, the 2000VSi-ECX cooling unit will fit in between studs and/or above door frames. Dual independent variable-speed fans offer flexibility to trade-off between super-quiet operation vs maximum performance.
All air-cooled refrigeration equipment requires fresh air intake to dissipate the heat generated by the cooling unit. The fresh air intake CANNOT come from the wine cellar space - it must come from space outside the cellar.
♦ View more of our CellarPro Products
♦ Click to view more CellarPro Units
- Features energy-efficient EC Fans on both the cold and hot sides
- Intuitive LED display panel mounted on the evaporator with digital programmable thermostat is simple and easy to use. Remote thermostat is available as an upgrade
- Adjustable humidity control combines a high-output compressor with flexible fan cycles to maintain a recommended level of moisture inside your cellar.
- Commercial-grade Electrofin coating protects the evaporator and condenser coils from leaks and corrosion.
- Low profile for maximum flexibility
- Shallow height fits above doors: 13 1/4" H
- Shallow width fits in between studs: 14 1/8" W
- Variable-speed fan inside the cellar
- 1886 BTUH on high fan speed
- 1713 BTUH on low fan speed
- Variable-speed fan outside the cellar
- 110F maximum intake temperature / 61.5 dBA on the high fan speed
- 100F maximum intake temperature / 55.5 dBA on the low fan speed
- Condensate management system
- Oversized stainless-steel drain pan
- 1/2" ID drain line for excess condensate
- Optional 100W heating element
- Energy-saver mode, quick-chill mode, and auto-defrost cycle provide convenient solutions to common cellar needs.
- Temperature set point range is 47F to 62F when the cooling unit is properly sized.
- Unit operates with minimal vibrations and less noise than comparable units from competitors.
- Audible and visual alarms and maintenance-needed indicator protect the cooling unit and the wine cellar.
- With dual power sources and a 10-foot power cord, the unit can be plugged into a receptacle from either the front or the rear of the cooling unit, providing flexibility for most installations.
- Common dedicated 15-amp circuit is required to power the unit.
- Our easy-access air filter protects the condenser coils and increases the expected useful life of the cooling unit.
- Adjustable mounting brackets, included as standard equipment, ensure easy installation.
- Removable steel case and refrigerant access valve provides access to the internal components for servicing and repair.
- CellarPro's 5-Year Standard Warranty, the most thorough in the industry, protects the unit against manufacturing defects.
- An optional Extended Warranty (P/N 1836) is available for additional protection.
- ETL Tested and Certified to rigorous UL Standards for safety.
- Model: 2000VSi-ECX
- Cellar Size(Nominal Cu Ft)*: 400
- Compressor Size (HP): 1/4 Ton
- BTUH @ 55F: 1886
- CFM (High Fan Speed): 188
- Decibels (Low Fan Speed): 56/ 56
- Installation Environment: Indoor
- Ambient Intake Range: -20** to 110F
- Power: 115V AC/ 60Hz
- Amps (Starting/Running): 22.2/ 4.0
- Dedicated Circuit: 15-Amp
- Refrigerant: R134a
- Drain Line: Included -1/2" ID
- Ducting - Cold Side: Yes –6" Diam.
- Ducting - Hot Side: Yes –6" Diam.
Dimensions
- Size (W x D x H -inches): 14.1 x 22.3 x 13.3
- Weight (lbs): 85
- CellarPro 2000VSi-ECX units are self-contained, fully-charged units designed to be attached to the ceiling inside the cellar, or above the cellar.
- 2000VSi-ECX units also can be located remotely from the cellar with the addition of one of our cold-side duct packages. Offered with or without insulated flex ducting, in a choice of configurations for low or high humidity conditions, our cold-side duct packages allow these cooling units to be ducted up to 50 equivalent feet (25' per duct). Ducting must be 8-inch (or greater) from start to finish.
- When calculating equivalent feet, each 90-degree turn counts for 8 feet.
- For remote or inaccessible installations, we offer a remote control display kit which is wired to the cooling unit and allows the digital display to be mounted inside or outside the cellar.
- 2000VSi-ECX cooling units require fresh air intake without interference from the unit's hot air exhaust. If sufficient space does not exist to provide fresh air, you may need our hot-side duct kit.
- If the fresh air intake (on the hot side) will pull air below below 40F, the cooling unit will require our Compressor Heater (P/N 1727) .
- If the fresh air intake (on the hot side) will pull air below 20F down to -20F, we recommend our Fan-Cycling Switch (P/N 6972) combined with our compressor heater.
- The cooling unit should never be exposed to temperatures below 32F.
- A CellarPro cooling unit must always be used in the upright position, and should never be operated on its side or upside down.