- Overview
- Features
- Tech Specs
- Configurations
- PDF Downloads
- Product Videos
- Reviews
- Cooling Capacity @ 13 C: 1253 BTUH
- Airflow: 90 cfm (cubic feet per minute)
- Cooling Unit dBA: 47
- Power: 220V AC / 50-60Hz
- Refrigerant: R134A
CellarPro 1800XT-ECX-220V Cooling Unit (P/N 1130). NOW WITH ENERGY-EFFICIENT EC FANS! CellarPro engineered the 1800XT-ECX-220V cooling unit to maintain ideal temperature and humidity conditions in geographies that use 220V / 1 Phase power (50 or 60 Hz).
All air-cooled refrigeration equipment requires fresh air intake to dissipate the heat generated by the cooling unit. The fresh air intake CANNOT come from the wine cellar space - it must come from space outside the cellar. Designed for indoor use only, 1800XT-ECX-220V units can operate in environments ranging from 35C to 4C out of the box.
♦ View more of our CellarPro Products
♦ Click to view more CellarPro Units
- Now with energy-efficient EC Fans on both the cold and hot sides, save $26.02 in annual energy costs vs AC fans (assumes 75% runtime and $0.15/kWh)
- This unit offers a choice of top or rear hot exhaust.
- Adjustable humidity control combines a high-output compressor with flexible fan cycles to maintain a recommended level of moisture inside your cellar.
- Extra-large coils generate maximum cooling power.
- Commercial-grade Electrofin coating protects the evaporator coils from leaks and corrosion.
- Intuitive LED display panel mounted on the evaporator with digital programmable thermostat is simple and easy to use. Remote thermostat is available as an upgrade.
- Energy-saver mode, quick-chill mode, and auto-defrost cycle provide convenient solutions to common cellar needs.
- Temperature set point range is 8.3C to 16.7C when the cooling unit is properly sized.
- Unit operates with minimal vibrations and less noise (46 dBA @ 50Hz and 50 dBA @ 60Hz).
- Audible and visual alarms and maintenance-needed indicator protect the cooling unit and the wine cellar.
- 8-foot power cord exits from the rear .
- Removable steel case provides access to the internal components for servicing and repair.
- CellarPro's 2-Year Standard Warranty, the most thorough in the industry, protects the unit against manufacturing defects.
- Model: 1800XT-ECX
- Cellar Size (Nominal Cu Ft): 250
- Cooling Capacity @ 13 C: 1253 BTUH
- Compressor Size (HP): 1/8 Ton
- CFM: 90
- Cooling Unit dBA: 47
- Power: 220V AC / 50-60Hz
- Amps (Starting / Running): 8.0-9.2 / 1.7
- Ambient Intake Range: -20** to 95F
- Dedicated Circuit: 15 Amp
- Refrigerant: R134A
- Drain Line: Optional - 1/2" ID .
- Ducting -Hot Side: Optional - 6" Diam.
Dimensions
- Size (W x D x H -inches): 18.1 x 16.5 x 10.6
- Weight (lbs): 60
- On the hot side, this unit intakes from the rear, and offers a choice of top or rear hot exhaust.
- On the cold side, this unit intakes from the front and exhausts from the bottom (thus the front 8 inches of the cooling unit must be inside the cellar.)
- The 1800XT-ECX requires fresh air intake at the rear of the cooling unit. If sufficient space does not exist to provide sufficient airflow to the rear of the cooling unit, you may need a rear duct kit.
- 1800 Series cooling units can be installed completely inside the wine cellar when used with our rear duct kit, which allows you to duct the supply and return airflows from the rear of the cooling unit up to 100 equivalent feet (50 feet per duct).
- Please note: The cold side of the 1800 Series cooling units cannot be ducted, and the hot side can be ducted with 6-inch ducting (no reductions) plus auxiliary fan support, which is included with our our rear duct kit.
- You must located this unit within the cellar, with the following exception: these units can be installed directly above the wine cellar when used with our front intake hood.
- For installation in environments below 40F, our compressor heater modification is required.
- For installation in environments below 20F down to -20F, we recommend our Fan-Cycling Switch (P/N 6972) combined with our compressor heater.
- A CellarPro cooling unit must always be used in the upright position, and should never be operated on its side or upside down.