- Cooling Capacity @ 55 F: 1456 BTUH
- Airflow: 90 cfm (cubic feet per minute)
- Cooling Unit dBA: 47
- Power: 115V AC / 60Hz
- Refrigerant: R134A
CellarPro 1800XT-EC Cooling Unit (P/N 36010). NOW WITH AN ENERGY-EFFICIENT EC FAN ON THE COLD SIDE! CellarPro engineered the 1800XT-ECX cooling unit for spaces that need extra BTUH and cooling capacity because of warm environments and/or the demands of a commercial establishment. 1800XT-EC units are more powerful than CellarPro 1800QTL-EC and 1800QT-EC units, but also somewhat louder.
All air-cooled refrigeration equipment requires fresh air intake to dissipate the heat generated by the cooling unit. The fresh air intake CANNOT come from the wine cellar space - it must come from space outside the cellar. Designed for indoor use only, 1800XT-EC units can operate in environments ranging from 95F to 40F out of the box.
♦ View more of our CellarPro Products
♦ Click to view more CellarPro Units
- CellarPro 1800XT-EC units are sized to replace Breezaire 2200 and Wine-Mate 2500 cooling units. Please confirm equivalent dimensions and airflow prior to purchase.
- Now with an energy-efficient EC Fans on the cold side
- This unit offers a choice of top or rear hot exhaust. If the unit's location does not provide sufficient room for airflow, you may need to purchase a rear duct kit.
- Adjustable humidity control combines a high-output compressor with flexible fan cycles to maintain a recommended level of moisture inside your cellar.
- Extra-large coils generate maximum cooling power.
- Commercial-grade Electrofin coating protects the evaporator coils from leaks and corrosion.
- Intuitive LED display panel mounted on the evaporator with digital programmable thermostat is simple and easy to use. Remote thermostat is available as an upgrade.
- Energy-saver mode, quick-chill mode, and auto-defrost cycle provide convenient solutions to common cellar needs.
- Temperature set point range is 47F to 62F when the cooling unit is properly sized.
- Unit operates with minimal vibrations and less noise than comparable units from competitors.
- Audible and visual alarms and maintenance-needed indicator protect the cooling unit and the wine cellar.
- 8-foot power cord exits from the rear and plugs into standard 110V receptacles.
- Common dedicated 15-amp circuit is required to power the unit.
- 3-amp electric receptacle is provided to run a small lamp.
- Removable steel case provides access to the internal components for servicing and repair.
- CellarPro's 5-Year Standard Warranty, the most thorough in the industry, protects the unit against manufacturing defects.
- An optional Enhanced Warranty (#1835) is available for additional protection.
- ETL Tested and Certified to rigorous UL Standards for safety.
- Model: 1800XT-EC
- Cooling Capacity @ 55 F: 1065 BTUH
- Compressor Size (HP): 1/6 Ton
- CFM: 90
- Cooling Unit dBA: 47
- Power: 115V AC / 60Hz
- Amps (Starting / Running): 20.1 / 2.95
- Ambient Intake Range: -20** to 95F
- Dedicated Circuit: 15 Amp
- Refrigerant: R134A
- Drain Line: Optional - 1/2" ID .
- Ducting -Hot Side: Optional - 6" Diam.
- Safety: ETL certified
Dimensions
- Size (W x D x H -inches): 18 x 16.5 x 10.5
- Weight (lbs): 60
- On the hot side, this unit intakes from the rear, and offers a choice of top or rear hot exhaust.
- On the cold side, this unit intakes from the front and exhausts from the bottom (thus the front 8 inches of the cooling unit must be inside the cellar.)
- The 1800XT-EC requires fresh air intake at the rear of the cooling unit. If sufficient space does not exist to provide sufficient airflow to the rear of the cooling unit, you may need a rear duct kit.
- 1800 Series cooling units can be installed completely inside the wine cellar when used with our rear duct kit, which allows you to duct the supply and return airflows from the rear of the cooling unit up to 100 equivalent feet (50 feet per duct).
- Please note: The cold side of the 1800 Series cooling units cannot be ducted, and the hot side can be ducted with 6-inch ducting (no reductions) plus auxiliary fan support, which is included with our our rear duct kit.
- You must located this unit within the cellar, with the following exception: these units can be installed directly above the wine cellar when used with our front intake hood.
- For installation in environments below 40F, our compressor heater modification is required.
- For installation in environments below 20F down to -20F, we recommend our Fan-Cycling Switch (P/N 6972) combined with our compressor heater.
- A CellarPro cooling unit must always be used in the upright position, and should never be operated on its side or upside down.